Какав је однос између тачности и стабилности мерача протока гаса?
A gas flow meter is a device used to measure the gas flow rate, and its accuracy and stability are important indicators to evaluate the performance of the flow meter. Accuracy refers to the deviation between the measurement result and the actual value, while stability refers to the degree of fluctuation of the measurement result within a certain time range. There is a certain correlation between accuracy and stability, and the relationship between them will be analyzed from different perspectives below.
Firstly, both accuracy and stability are affected by the structure and characteristics of the gas flow meter itself. The structure and characteristics of the flow meter determine the limitations of its measurement accuracy and stability for the gas flow rate. For example, the flow channel design of the flow meter, the sensitivity and response speed of the sensor, the thermal expansion coefficient of the flow meter material, etc., will all have an impact on the flow measurement result. If the flow channel design is unreasonable or the sensitivity of the sensor is not high enough, it will cause poor measurement accuracy and stability of the flow meter.
Secondly, accuracy and stability are also related to the fluid properties. Different gases have different physical characteristics, such as density, viscosity, and compression coefficient, which will affect the measurement result of the gas flow meter. For example, the greater the density of the gas, the more difficult it is to measure the flow rate, and the accuracy and stability of the flow meter will also be affected to a certain extent. In addition, the compression coefficient of the gas will also cause changes in the accuracy and stability of the gas flow meter, which needs to be considered in the design and use.
Thirdly, environmental conditions will also affect the accuracy and stability of the gas flow meter. Flow meters are usually installed in the on-site environment for gas flow measurement, and changes in environmental temperature, humidity, pressure, and other conditions can all affect the performance of the flow meter. For example, in a high-temperature environment, the material of the flow meter may expand, causing a deviation in the measurement result; while in a high-humidity environment, the sensor of the flow meter may be affected by water vapor and lose accuracy and stability.
Meanwhile, the service life of the gas flow meter will also affect its accuracy and stability. With the increase of usage time, the structure and characteristics of the flow meter may change, resulting in a decrease in measurement accuracy and stability. Therefore, regular maintenance and calibration are very important to ensure the accuracy and stability of the flow meter.
Укратко, тачност и стабилност мерача протока гаса заједнички одређују више фактора као што су структура и карактеристике самог мерача протока, својства флуида, услови околине и радни век. Постоји одређена корелација између тачности и стабилности. Мере као што су оптимизација структуре и карактеристика мерача протока, разумно бирање особина флуида и услова околине, и редовно одржавање и калибрација могу побољшати тачност и стабилност мерача протока. Само разматрањем и усавршавањем свих аспеката могу се добити прецизнији и стабилнији резултати мерења протока гаса.
О нама.
Схенианг ХОлиан Прецисион инструмент цо., Лтд основана 2017. године, специјализована је за производњу прибора за генератор кисеоника: минијатурни соленоидни вентил за преносни медицински генератор кисеоника, 4-струки 2 положаја медицински генератор кисеоника, електромагнетни вентил за генератор медицинског кисеоника од 3Л до 10Л, склоп регулатора притиска за Концентратор кисеоника, Склоп за смањење притиска за концентратор кисеоника, Пинхоле мерач протока кисеоника цонцентрарор, мерач протока са рупама медицинског концентратора кисеоника, мерач протока од 5Л за концентратор кисеоника, Специјални противпожарни вентил за концентратор кисеоника, Фиресафе канила вентил конектор цеви за довод кисеоника, примарни филтер кисеоника, филтер медицинског квалитета, контролни вентил (материјал ПА6), неповратни вентил (материјал) ),Прибор за генератор кисеоника Глава резервоара за молекуларно сито, Кисеоник Додаци за концентратор Ваздушни филтери, Додаци за концентратор кисеоника НПТ1/8-∅8 конектор, Додаци за концентратор кисеоника НПТ1/8-∅10 конектор, Додаци за концентратор кисеоника 3-смерна млазница, Додаци за концентратор кисеоника 90° млазница, производња калупа и бризгање.